Open type diesel generator set
Category: Diesel Generator Set
Standby / prime power for industrial plants: manufacturing factories, mines, metallurgy and chemical industries.Infrastructure and public facilities: highway service areas, commercial buildings, shopping malls, hospitals and schools.Data centers and communication base stations: uninterrupted emergency power supply.Overseas trade projects: power supply for overseas projects, oilfields and camps in Southeast Asia, Central Asia and the Middle East.Special scenarios: municipal engineering, field operations and high-power power supply for temporary construction sites.
2. Structural Features of Open Type Units
Adopt open frame base with solid structure and high heat dissipation efficiency, suitable for well-ventilated machine rooms.Integrated shock-absorbing base reduces vibration transmission during operation.Equipped with independent heat dissipation cover and high-power radiator to ensure stable operation under high temperature.Split-type intelligent control panel realizes visual operation, and fault codes can be checked with one click.Modular design provides sufficient space for later maintenance, enabling easy disassembly and assembly of components.
Performance Features: 1️⃣ Multiple generating sets can be paralleled to form a power grid with automatic load distribution, ensuring more reliable power supply.2️⃣ Centralized scheduling enables easier maintenance and servicing. 3️⃣ Higher cost‑effectiveness: appropriate units can be put into operation according to load demand, reducing fuel and lubricant consumption. 4️⃣ High flexibility for future expansion: additional generating sets can be deployed on demand to meet increased load requirements.
Market Price:
Serial Number:
Weight:
Supply
隐藏域元素占位
Product Introduction
Open Type Diesel Generator Set Solution
1. Product Overview
1.1 Product Introduction
This open type diesel generator set covers power range from 20kW to 3000kW, meeting power supply demands of diverse scenarios. Optional electrical specifications: Frequency 50Hz/60Hz; Output Voltage 400V/690V/10.5kV. The picture and technical parameters take the 800kW open type diesel generator set as an example.
1.2 Key Technical Parameters (800kW Model)
| Item | Specification |
|---|---|
| Prime Power | 800kW/1000kVA |
| Standby Power | 880kW/1100kVA |
| Frequency (Hz) | 50 |
| Voltage (V) | 400 |
| Phase | 3-Phase |
| Power Factor | 0.8 |
| Engine Model | Cummins KTA38-G5 |
| Engine Speed (RPM) | 1500 |
| Alternator Model | Stamford S6L1D-E4 |
| Control System | SmartGen |
| Continuous Running Time with Full Tank (h) | N/A |
| Fuel Consumption at 110% Load (g/kW·h) | 200 |
| Fuel Consumption at 100% Load (g/kW·h) | 202 |
| Fuel Consumption at 75% Load (g/kW·h) | 207 |
| Fuel Consumption at 50% Load (g/kW·h) | 218 |
| Net Weight (kg) | 8280 |
| Length L (mm) | 4300 |
| Width W (mm) | 1770 |
| Height H (mm) | 2470 |
| Fuel Tank Capacity (L) | N/A |
2. Adopted Standards
- GB/T2820.5
- ISO8528-5
3. Ambient Operating Conditions
- Ambient Temperature: 5℃ ~ 40℃
- Altitude: ≤1000m
4. Factory Testing Items
Each unit undergoes comprehensive inspection before delivery to guarantee stable operation:
- Stepwise Load Test: 0%, 25%, 50%, 75%, 100%, 110% full-range load test
- Complete Function Test
- Safety Protection Function Test
5. Core Product Advantages
5.1 Wide Power Coverage
Full power range from 20kW to 3000kW, suitable for small residential, medium commercial, large industrial construction, data center, mine, oilfield and other scenarios. Three voltage options (400V low voltage / 690V industrial medium voltage / 10.5kV high voltage), dual frequency 50/60Hz adaptable for domestic markets and overseas markets including Middle East, Southeast Asia and Central Asia.
5.2 World-Class Core Components
- Engine: Adopts premium Cummins power unit (Model KTA38-G5 as sample) with sufficient power reserve, outstanding durability and long overhaul cycle.
- Alternator: Stamford brushless synchronous alternator with excellent voltage & frequency stabilization, low waveform distortion, ideal for powering precision equipment.
- Control System: SmartGen intelligent controller, supporting auto start/stop, remote monitoring, automatic fault alarm and multi-protection logic.
5.3 Controllable Fuel Economy
Standardized fuel consumption data under multiple working conditions from 50% light load to 110% overload, convenient for customers to calculate long-term operation cost. The 800kW model only consumes 202g/kW·h at full load with excellent energy-saving performance.
5.4 Strict Factory Inspection
Testing procedures exceed national standards with long-duration full-load & over-load verification. Triple tests on electric, mechanical and protection systems greatly reduce factory failure rate.
5.5 Standard Compliance
Manufactured in strict accordance with China national standard GB/T2820.5 and international standard ISO8528-5 for generator sets, fully meeting compliance requirements for domestic bidding projects and overseas export certifications.
6. Selection Instructions
- Distinction between Prime Power & Standby Power
- Prime Power: For long-term continuous operation, allows short-time 110% overload within 1 hour
- Standby Power: For short-time emergency power failure use, not allowed for long-term full-load continuous operation
- Altitude & Temperature Limitation: Power derating calculation is required when altitude exceeds 1000m or ambient temperature exceeds 40℃
- Custom Voltage & Frequency: Default 50Hz/400V for domestic projects; customized 60Hz for export countries and high voltage 10.5kV available on request
- Optional Accessories: External daily fuel tank, soundproof canopy, parallel module, ATS automatic transfer switch cabinet, remote cloud monitoring system can be equipped as required
7. Quality & After-Sales Support
- Manufactured complying with both national and international standards; every unit passes multi-stage load test before delivery
- Global warranty for core power (Cummins) and alternator (Stamford), complete spare parts supply channels at home and abroad
- Full set of supporting services available including on-site commissioning, machine room planning, operation & maintenance training and annual maintenance
- Customization supported for all power ranges to meet special working conditions (low temperature, heavy dust, anti-corrosion modification)
Title
Open Type Diesel Generator Set 50Hz | 60Hz 400V | 690V | 10.5kV 20kW - 3000kW
| Parameter Item | Specification |
|---|---|
| Prime Power | 800kW/1000kVA |
| Standby Power | 880kW/1100kVA |
| Frequency (Hz) | 50 |
| Voltage (V) | 400 |
| Phase | 3 |
| Power Factor | 0.8 |
| Engine Model | Cummins KTA38-G5 |
| Engine Speed (RPM) | 1500 |
| Alternator Model | Stamford S6L1D-E4 |
| Control System | SmartGen |
| Continuous Running Time with Full Tank (h) | N/A |
| Fuel Consumption at 110% Load (g/kW·h) | 200 |
| Fuel Consumption at 100% Load (g/kW·h) | 202 |
| Fuel Consumption at 75% Load (g/kW·h) | 207 |
| Fuel Consumption at 50% Load (g/kW·h) | 218 |
| Net Weight (kg) | 8280 |
| Length L (mm) | 4300 |
| Width W (mm) | 1770 |
| Height H (mm) | 2470 |
| Fuel Tank Capacity (L) | N/A |
Adopted Standards
- GB/T2820.5
- ISO8528-5
Ambient Conditions
- Temperature: 5℃ ~ 40℃
- Altitude: ≤1000m
Factory Testing
- 0%, 25%, 50%, 75%, 100%, 110% Load Test
- Function Test
- Protection Test
Keywords: Open type diesel generator set
Prev: Nothing!
Other products
Product Inquiry
You can contact us by any convenient means, and we offer 24/7 services via phone or email. We’re happy to answer your questions.